Specifications

Supply Voltage

24V dc

Safety Contacts

2

Function

Two Hand Control

Auxiliary Contacts

2

Range

Preventa XPS

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

SIL IEC 61508

3

SIL (IEC 61508)

3

Terminal Type

Screw

Series

XPSBF

Width

22.5mm

Depth

114mm

Performance Level

e

Length

99mm

Product details

Schneider Electric Preventa XPS BF Two Hand Control Monitoring Type IIIC Safety Relay Module.

From Schneider Electric we offer you the Preventa XPS range of Safety relays (safety modules) providing the solution and answer to monitoring safety relay functions. The relays include redundancy principle micro-pressor technology providing you with advanced functionality. There are various safety relay models to choose from, including removeable terminal block versions, allowing easy selection of a module to monitor a safety functions.

Features.

  • Emergency stop and switches

  • Coded magnetic switches

  • Enabling switch

  • Sensing mats and edges

  • Two-hand control

  • Light curtains

  • Zero speed

  • Time delay

  • Lifts

  • Other applications on hydraulic and eccentric presses.

The safety relays are suitable for all applications with hazards and protect machines and operators.

These safety modules can be used in conjunction with the Harmony XY2SB range of two-hand control stations

What Safety Relay should I use with a Two Hand Control Station?

  • Safety modules XPS BA, BC and BF may be used for two-hand control stations in order to comply with the requirements of European standard EN 574/ISO 13851 for two-hand control systems.

Approvals

BG, UL, CSA

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

EGP 20,651.13

Each (ex VAT)

Schneider Electric Preventa XPS XPSBF Two Hand Control Safety Relay, 24V dc, 2 Safety Contacts

EGP 20,651.13

Each (ex VAT)

Schneider Electric Preventa XPS XPSBF Two Hand Control Safety Relay, 24V dc, 2 Safety Contacts
Stock information temporarily unavailable.

Technical Document

Specifications

Supply Voltage

24V dc

Safety Contacts

2

Function

Two Hand Control

Auxiliary Contacts

2

Range

Preventa XPS

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

SIL IEC 61508

3

SIL (IEC 61508)

3

Terminal Type

Screw

Series

XPSBF

Width

22.5mm

Depth

114mm

Performance Level

e

Length

99mm

Product details

Schneider Electric Preventa XPS BF Two Hand Control Monitoring Type IIIC Safety Relay Module.

From Schneider Electric we offer you the Preventa XPS range of Safety relays (safety modules) providing the solution and answer to monitoring safety relay functions. The relays include redundancy principle micro-pressor technology providing you with advanced functionality. There are various safety relay models to choose from, including removeable terminal block versions, allowing easy selection of a module to monitor a safety functions.

Features.

  • Emergency stop and switches

  • Coded magnetic switches

  • Enabling switch

  • Sensing mats and edges

  • Two-hand control

  • Light curtains

  • Zero speed

  • Time delay

  • Lifts

  • Other applications on hydraulic and eccentric presses.

The safety relays are suitable for all applications with hazards and protect machines and operators.

These safety modules can be used in conjunction with the Harmony XY2SB range of two-hand control stations

What Safety Relay should I use with a Two Hand Control Station?

  • Safety modules XPS BA, BC and BF may be used for two-hand control stations in order to comply with the requirements of European standard EN 574/ISO 13851 for two-hand control systems.

Approvals

BG, UL, CSA

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088