RS PRO, Fire Performance 2 Core, Red Power Cable
Technical Document
Specifications
Brand
RS ProCross Sectional Area
1.5 mm²
Number of Cores
2
Sheath Colour
Red
Length
100m
Cable Type
Fire Performance
Current Rating
19.5 A
Outer Diameter
8.3mm
Voltage Rating
500 V
Conductor Strand Type
Solid
Core Strands
1.5/7.6 mm
Conductor Material
Copper
Size of Strands
7.6 mm
PRICED TO CLEAR
Yes
Maximum Operating Temperature
+90°C
American Wire Gauge
15 AWG
Conductor Resistance
12.1 Ω/km
Insulation material
Silicone
Minimum Operating Temperature
-40°C
Standards Met
BASEC
Country of Origin
United Kingdom
Product details
Fire Performance Cable
Fast and easy to prepare for termination, no troublesome multiple sheaths, foils or wraps to strip. Superb working flexibility and stays where you put it, reducing time and costs. Ideal for emergency lighting. Also suitable for automatic lift doors, air conditioning and computer control where low smoke, fume and zero halogen cable is required.
Features and Benefits
Red and white sheaths available
Aluminium / co-polymer foil screen
12 twists per metre for data protection
Approved by LPCB and BASEC to meet with BS5839-1:2002 + A2 : 2008 Clause 26.2d, BS EN 50200:2006 + Annex E 30 Minutes & BS EN 50200: 2006 Class PH120
Fire resistant
Operating temperature range -40° to +90°C
Low smoke zero halogen
Product Application Information
Ideal for long cable runs and analogue addessable fire systems.
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
RS ProCross Sectional Area
1.5 mm²
Number of Cores
2
Sheath Colour
Red
Length
100m
Cable Type
Fire Performance
Current Rating
19.5 A
Outer Diameter
8.3mm
Voltage Rating
500 V
Conductor Strand Type
Solid
Core Strands
1.5/7.6 mm
Conductor Material
Copper
Size of Strands
7.6 mm
PRICED TO CLEAR
Yes
Maximum Operating Temperature
+90°C
American Wire Gauge
15 AWG
Conductor Resistance
12.1 Ω/km
Insulation material
Silicone
Minimum Operating Temperature
-40°C
Standards Met
BASEC
Country of Origin
United Kingdom
Product details
Fire Performance Cable
Fast and easy to prepare for termination, no troublesome multiple sheaths, foils or wraps to strip. Superb working flexibility and stays where you put it, reducing time and costs. Ideal for emergency lighting. Also suitable for automatic lift doors, air conditioning and computer control where low smoke, fume and zero halogen cable is required.
Features and Benefits
Red and white sheaths available
Aluminium / co-polymer foil screen
12 twists per metre for data protection
Approved by LPCB and BASEC to meet with BS5839-1:2002 + A2 : 2008 Clause 26.2d, BS EN 50200:2006 + Annex E 30 Minutes & BS EN 50200: 2006 Class PH120
Fire resistant
Operating temperature range -40° to +90°C
Low smoke zero halogen
Product Application Information
Ideal for long cable runs and analogue addessable fire systems.