Technical Document
Specifications
Brand
John DrummondMaximum Voltage
500V ac/dc
Safety Category
CAT III 1000 V, CAT IV 600V
Display Type
LED
IP Rating
IP67
Calibrated
RSCAL
Power Source
Mains
Dimensions
213 x 112 x 72mm
Weight
320g
Height
72mm
Length
213mm
Maximum Operating Temperature
+55°C
Width
112mm
Minimum Operating Temperature
-10°C
Model Number p
DRUMTL10
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600 V, 1000 V
Model Number (p)
DRUMTL10
Country of Origin
Philippines
Product details
Drummond Test Lamps MTL10
Bright LED indication of voltage between 50V and 500V AC/DC
Four distinct bands of illumination above 50, 100, 200 and 400V AC/DC with a 360o viewing angle even in bright sunlight
Identifies potentially lethal voltages at 50V and distinguishes between 110V, 230V and phase to phase voltages in 3 phase systems
Finger shields and insulated probe tips with only 4mm of exposed metal
Double insulated cable with white inner insulation gives a clear warning of abrasion and is heat and oil resistant
Meets the recommendations of the UK Health and Safety Executive in their guidance notes on the electricians test lamp (GS38)
Complies with BS EN 61243-3 and BS EN 61010. CAT IV 600V, CAT III 1000V
No batteries required
Supplied with
Carry case, right angled probe tip, two straight tips and instructions
Mains Voltage Indicators - Contact
Stock information temporarily unavailable.
Please check again later.
EGP 19,943.11
Each (ex VAT)
1
EGP 19,943.11
Each (ex VAT)
1
Technical Document
Specifications
Brand
John DrummondMaximum Voltage
500V ac/dc
Safety Category
CAT III 1000 V, CAT IV 600V
Display Type
LED
IP Rating
IP67
Calibrated
RSCAL
Power Source
Mains
Dimensions
213 x 112 x 72mm
Weight
320g
Height
72mm
Length
213mm
Maximum Operating Temperature
+55°C
Width
112mm
Minimum Operating Temperature
-10°C
Model Number p
DRUMTL10
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600 V, 1000 V
Model Number (p)
DRUMTL10
Country of Origin
Philippines
Product details
Drummond Test Lamps MTL10
Bright LED indication of voltage between 50V and 500V AC/DC
Four distinct bands of illumination above 50, 100, 200 and 400V AC/DC with a 360o viewing angle even in bright sunlight
Identifies potentially lethal voltages at 50V and distinguishes between 110V, 230V and phase to phase voltages in 3 phase systems
Finger shields and insulated probe tips with only 4mm of exposed metal
Double insulated cable with white inner insulation gives a clear warning of abrasion and is heat and oil resistant
Meets the recommendations of the UK Health and Safety Executive in their guidance notes on the electricians test lamp (GS38)
Complies with BS EN 61243-3 and BS EN 61010. CAT IV 600V, CAT III 1000V
No batteries required
Supplied with
Carry case, right angled probe tip, two straight tips and instructions