Technical Document
Specifications
Brand
Phoenix ContactMaximum Load Current
9 A
Mounting Type
DIN Rail
Maximum Load Voltage
440 V ac
Minimum Load Voltage
110 V ac
Maximum Control Voltage
24 V dc
Terminal Type
Screw
Output Device
Triac
Maximum Turn On Time
20ms
Load Voltage Range
110 → 440V ac
Dimensions
84 x 62 x 110mm
Height
110mm
Off State Leakage Current
7 mA
Length
84mm
Operating Temperature Range
-20 → +60°C
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Depth
62mm
Country of Origin
Germany
Product details
ELR Series load and interface relay
Electronic interface relays replace an entire reversing contactor circuit - including control input and load wiring lock mechanism. Contactless switching in the voltage zero point does not generate additional high-frequency interfering pulses. Input and load end suppressors permit permanently reliable operation, even with inductive loads.
ELR 3 / 9-400
Electronic load relay with 62 mm overall width
Input voltage 24V dc
Operating indicator
Protective circuit in input and output
ELR W3 / 9-400
Electronic interface relay with 62 mm overall width
Input voltage 24 Vdc
Load end 110–440 VAC maximum 9 A (see derating curve)
Zero Voltage Relays
Stock information temporarily unavailable.
Please check again later.
EGP 22,239.72
Each (ex VAT)
1
EGP 22,239.72
Each (ex VAT)
1
Technical Document
Specifications
Brand
Phoenix ContactMaximum Load Current
9 A
Mounting Type
DIN Rail
Maximum Load Voltage
440 V ac
Minimum Load Voltage
110 V ac
Maximum Control Voltage
24 V dc
Terminal Type
Screw
Output Device
Triac
Maximum Turn On Time
20ms
Load Voltage Range
110 → 440V ac
Dimensions
84 x 62 x 110mm
Height
110mm
Off State Leakage Current
7 mA
Length
84mm
Operating Temperature Range
-20 → +60°C
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Depth
62mm
Country of Origin
Germany
Product details
ELR Series load and interface relay
Electronic interface relays replace an entire reversing contactor circuit - including control input and load wiring lock mechanism. Contactless switching in the voltage zero point does not generate additional high-frequency interfering pulses. Input and load end suppressors permit permanently reliable operation, even with inductive loads.
ELR 3 / 9-400
Electronic load relay with 62 mm overall width
Input voltage 24V dc
Operating indicator
Protective circuit in input and output
ELR W3 / 9-400
Electronic interface relay with 62 mm overall width
Input voltage 24 Vdc
Load end 110–440 VAC maximum 9 A (see derating curve)