Huber+Suhner, Plug Cable Mount MMCX Connector, 50Ω, Solder Termination, Straight Body

RS Stock No.: 612-7381Brand: Huber+SuhnerManufacturers Part No.: 11_MMCX-50-2-1/111_OE
brand-logo
View all in Coaxial Connectors

Technical Document

Specifications

Country of Origin

Switzerland

Product details

PAC12 Oscilloscope clamp for AC/DC current

The PAC12 current clamp accurately measures AC or DC currents by using the Hall-effect principle. The current clamp with mV output on BNC (direct reading on oscilloscopes, etc.) is equipped with an automatic DC Zero system.

Current calibres:
0.2 A AC to 40 A AC (60 A peak) / 0.4 A DC to 60 A DC
0.5 A AC to 400 A AC (600 A peak) / 0.5 A DC to 600 A DC
Output signal:
10 mV AC+DC / A AC+DC (0.6 V for 60 A)
1 mV AC+DC / A AC+DC (0.6 V for 600 A)
Max. jaw opening: 31 mm
Battery: 9 V alkaline (NEDA 1604A, IEC 6LR61)

Supplied with

Battery and user’s manual.

Standards

IEC 1010-1 and IEC 1010-2-032, 600 V category III pollution degree 2, 300 V category IV pollution degree 2

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

EGP 1,229.20

Each (ex VAT)

Huber+Suhner, Plug Cable Mount MMCX Connector, 50Ω, Solder Termination, Straight Body

EGP 1,229.20

Each (ex VAT)

Huber+Suhner, Plug Cable Mount MMCX Connector, 50Ω, Solder Termination, Straight Body
Stock information temporarily unavailable.

Technical Document

Specifications

Country of Origin

Switzerland

Product details

PAC12 Oscilloscope clamp for AC/DC current

The PAC12 current clamp accurately measures AC or DC currents by using the Hall-effect principle. The current clamp with mV output on BNC (direct reading on oscilloscopes, etc.) is equipped with an automatic DC Zero system.

Current calibres:
0.2 A AC to 40 A AC (60 A peak) / 0.4 A DC to 60 A DC
0.5 A AC to 400 A AC (600 A peak) / 0.5 A DC to 600 A DC
Output signal:
10 mV AC+DC / A AC+DC (0.6 V for 60 A)
1 mV AC+DC / A AC+DC (0.6 V for 600 A)
Max. jaw opening: 31 mm
Battery: 9 V alkaline (NEDA 1604A, IEC 6LR61)

Supplied with

Battery and user’s manual.

Standards

IEC 1010-1 and IEC 1010-2-032, 600 V category III pollution degree 2, 300 V category IV pollution degree 2